Product Search
Top

Engine Management

Gasoline Engine
Management


Air/Fuel Ratio Sensor

Oxygen Sensor

Ceramic Substrate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air/Fuel Ratio Sensor


The air/fuel ratio sensor, installed in the exhaust manifold, detects the degree of the exhaust gas air/fuel ratio. Based on signals from the air/fuel ratio sensor, the engine ECU controls the air/fuel ratio in the combustion chamber (air/fuel ratio feedback control).

DENSO provides two types of air/fuel ratio sensors: a planar type and a thimble type.

 

DENSO Technology – Leading the World

In 1996, DENSO launched the world’s first air/fuel ratio sensor, achieving more precise control of the air/fuel ratio than is possible using a conventional oxygen sensor.


Benefits and Features

  • Quick activation of zirconia solid electrolyte
    • DENSO’s planar type air/fuel ratio sensor has a zirconia solid electrolyte integrated with an alumina heater substrate, allowing it to more quickly detect oxygen concentration with a light-off time of 10 seconds.
  • High-detection accuracy
    • Precisely controls the amount of oxygen ions that flow in the diffusion layer to limit current flow, resulting in high-accuracy detection.


Product Types

Product type Heater
Light-off time
(seconds)
Response time
(milliseconds)
Planar type Integrated with solid electrolyte
15
200
Thimble type Separated from solid electrolyte
20
200


Structure of Planar Air/Fuel Ratio Sensor

 